Welcome to WuJiGu Developer Q&A Community for programmer and developer-Open, Learning and Share
Welcome To Ask or Share your Answers For Others

Categories

0 votes
516 views
in Technique[技术] by (71.8m points)

postgresql - serial in postgres is being increased even though I added on conflict do nothing

I'm using Postgres 9.5 and seeing some wired things here.

I've a cron job running ever 5 mins firing a sql statement that is adding a list of records if not existing.

INSERT INTO 
   sometable (customer, balance)
VALUES
    (:customer, :balance)
ON CONFLICT (customer) DO NOTHING

sometable.customer is a primary key (text)

sometable structure is:
id: serial
customer: text
balance: bigint

Now it seems like everytime this job runs, the id field is silently incremented +1. So next time, I really add a field, it is thousands of numbers above my last value. I thought this query checks for conflicts and if so, do nothing but currently it seems like it tries to insert the record, increased the id and then stops.

Any suggestions?

Question&Answers:os

与恶龙缠斗过久,自身亦成为恶龙;凝视深渊过久,深渊将回以凝视…
Welcome To Ask or Share your Answers For Others

1 Answer

0 votes
by (71.8m points)

The reason this feels weird to you is that you are thinking of the increment on the counter as part of the insert operation, and therefore the "DO NOTHING" ought to mean "don't increment anything". You're picturing this:

  1. Check values to insert against constraint
  2. If duplicate detected, abort
  3. Increment sequence
  4. Insert data

But in fact, the increment has to happen before the insert is attempted. A SERIAL column in Postgres is implemented as a DEFAULT which executes the nextval() function on a bound SEQUENCE. Before the DBMS can do anything with the data, it's got to have a complete set of columns, so the order of operations is like this:

  1. Resolve default values, including incrementing the sequence
  2. Check values to insert against constraint
  3. If duplicate detected, abort
  4. Insert data

This can be seen intuitively if the duplicate key is in the autoincrement field itself:

CREATE TABLE foo ( id SERIAL NOT NULL PRIMARY KEY, bar text );
-- Insert row 1
INSERT INTO foo ( bar ) VALUES ( 'test' );
-- Reset the sequence
SELECT setval(pg_get_serial_sequence('foo', 'id'), 0, true);
-- Attempt to insert row 1 again
INSERT INTO foo ( bar ) VALUES ( 'test 2' )
     ON CONFLICT (id) DO NOTHING;

Clearly, this can't know if there's a conflict without incrementing the sequence, so the "do nothing" has to come after that increment.


与恶龙缠斗过久,自身亦成为恶龙;凝视深渊过久,深渊将回以凝视…